Optical patch cable LC/APC to LC/APC 9/125µm SM duplex, 7 m
Optical patch cable LC/APC to LC/APC 9/125µm SM duplex, 7 m
In cart {{totalProductsCount}} item(s)
Your cart is empty
Optical patch cable LC/APC to LC/APC 9/125µm SM duplex, 7 m
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Optical patch cable LC/APC to LC/APC 9/125µm SM duplex, 7 m
Optical patch cable LC/APC to LC/APC 9/125µm SM duplex, 7 m
Duplex single-mode optical patch cable with LC/APC connectors on both ends, 9/125 µm core/cladding and 7 m length. Designed for low-loss fibre connections in telecom, data centre and active equipment links, this LC/APC to LC/APC 9/125µm SM duplex cable provides reliable signal transmission and reduced back-reflection thanks to angled physical contact (APC) connectors. The 7 m length allows flexible routing between racks, panels and equipment while maintaining single-mode performance for long-reach and high-speed optical links.
The angled contact of LC/APC connectors minimizes back-reflection, improving return loss for sensitive optical systems. Single-mode 9/125 µm fibre ensures low attenuation and stable transmission over long distances. Duplex construction enables simultaneous bi-directional data flow with consistent polarity and compact LC connector form factor, saving panel space. The cable is suitable for precision optical links where low insertion loss and reliable mating are required.
Identify the correct ports on transceivers or patch panels and ensure both ends maintain proper polarity for bi-directional links. Remove protective dust caps from LC/APC connectors before insertion and inspect connector end-faces for contamination. Gently insert LC duplex connectors until they click into the adapter or transceiver port, avoiding excessive bending of the fibre cable; respect the minimum bend radius specified by the manufacturer. When disconnecting, pull by the connector body rather than the fibre jacket to avoid stressing the fibre.
Store and handle the patch cable in a clean environment; keep dust caps on when not in use. Use APC-to-APC connectors where low back-reflection is required, and verify end-face cleanliness with an inspection microscope. Route cables to avoid tight bends and mechanical strain, and label both ends for easy identification during maintenance.