Terminal strip PAWBOL LZ E.4007P — 4×16 mm², 76 A, model E.4007P
Terminal strip PAWBOL LZ E.4007P — 4×16 mm², 76 A, model E.4007P
In cart {{totalProductsCount}} item(s)
Your cart is empty
Terminal strip PAWBOL LZ E.4007P — 4×16 mm², 76 A, model E.4007P
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Terminal strip PAWBOL LZ E.4007P — 4×16 mm², 76 A, model E.4007P
Terminal strip PAWBOL LZ E.4007P — 4×16 mm², 76 A, model E.4007P
PAWBOL LZ E.4007P is a 4‑pole terminal strip designed for conductors up to 16 mm² and a continuous current rating of 76 A. The device provides screw‑clamp connections in a compact modular housing that is suitable for mounting in distribution blocks, control panels and junction points. The product is intended for reliable conductor termination and straightforward wiring tasks in both industrial and residential installations.
The terminal strip offers secure screw‑clamp terminations that maintain electrical contact under mechanical stress and vibration. Its four poles allow neat multi‑conductor assemblies while the insulated body reduces the risk of accidental short circuits. The compact footprint facilitates installation in crowded enclosures and simplifies maintenance by allowing individual conductors to be disconnected or replaced without disturbing adjacent connections.
This terminal strip is not intended for conductors larger than 16 mm² or for continuous currents exceeding 76 A. It is not a protective device and does not provide isolation or overcurrent protection by itself; appropriate protective devices and correct application of earthing and insulation must be used elsewhere in the installation. For outdoor or highly corrosive environments, additional protection against moisture and aggressive agents may be required.
Prepare conductor ends according to applicable standards, strip insulation to the recommended length and insert conductors fully into the screw‑clamp openings. Tighten screws to the torque specified by relevant installation norms to ensure reliable contact without damaging conductors. Mount the terminal strip securely in the intended enclosure or mounting rail, route wiring to avoid mechanical strain and verify connections with appropriate test equipment before energizing the circuit.
Use properly sized ferrules or correctly prepared solid/stranded conductors, apply the recommended screw torque, and include appropriate overcurrent protection in the circuit. Regularly inspect connections for signs of loosening or corrosion in installations subject to vibration or environmental exposure.