Leave your address - as soon as the price of the product goes down, you'll know about it right away
Circuit breaker Schneider Electric A9F03102 1P B 2A 6kA AC (IP20)
Circuit breaker Schneider Electric A9F03102 1P B 2A 6kA AC (IP20)
In cart {{totalProductsCount}} item(s)
Your cart is empty
Circuit breaker Schneider Electric A9F03102 1P B 2A 6kA AC (IP20)
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Circuit breaker Schneider Electric A9F03102 1P B 2A 6kA AC (IP20)
Circuit breaker Schneider Electric A9F03102 1P B 2A 6kA AC (IP20)
Schneider Electric A9F03102 is a single-pole miniature circuit breaker (1P) with a B tripping characteristic and a rated current of 2 A. Designed for residential and light commercial single-phase installations, the device provides overload and short-circuit protection with a breaking capacity of 6 kA (AC) and is intended for DIN-rail mounting in modular distribution boards. The breaker has IP20 protection and integrates into standard switchgear assemblies for circuit protection and distribution.
The compact iC60N format enables installation in distribution panels with limited space while maintaining standard modular compatibility. The B tripping curve ensures fast disconnection of low-level short-circuit currents common to lighting and small-appliance circuits, helping preserve selectivity with downstream protection. A 6 kA breaking capacity covers typical residential and light-commercial fault levels, and DIN-rail mounting simplifies replacement and upgrades without extensive rewiring.
This 2 A single-pole breaker is not intended for high-current feeders, three-phase installations, or motor protection where higher rated currents and different tripping characteristics (for example C or D) are required. It may also be inappropriate when prospective fault levels exceed 6 kA; in such cases select a breaker with a higher breaking capacity. Verify coordination with upstream and downstream protective devices to ensure selective operation.
With the supply isolated, snap the breaker onto a standard DIN rail inside the distribution board following local wiring regulations. Connect the incoming phase conductor to the line terminal and the outgoing conductor to the load terminal, tightening terminals to the manufacturer’s recommended torque. After wiring, switch the breaker on to restore the circuit and verify operation under a controlled load. Always de-energize the circuit before servicing or replacing the device and follow appropriate electrical safety procedures.
Use the Schneider Electric A9F03102 1P B 2 A breaker for low-current single-phase circuits such as lighting and small receptacle circuits; pair it with appropriate upstream protection and perform periodic inspections to ensure reliable operation.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}