Patch Panel Synergy21 S216384/S216317V4 — 12x TP-TP Couplers, CAT6A, includes Slim-line Keystone Couplings, Surface-Mount Metal Hinged Box, Black
Product description is under construction. Specify the parameters, price and delivery options before buying!
The Synergy21 S216384/S216317V4 patch panel supplies 12 TP‑TP couplers in CAT6A specification and includes Slim-line keystone couplings, pre-installed in a black surface‑mount metal hinged box. It is designed to terminate and protect horizontal copper cabling for 10 Gigabit Ethernet links while offering a compact, serviceable point for patching in server rooms, communications cabinets, or wall‑mounted installations where a neat, protected CAT6A outlet is required.
The unit combines CAT6A performance with keystone modularity, enabling use with a wide range of keystone jacks and simple field replacement of couplers. The slim-line keystone format reduces depth and saves space inside the surface‑mount box. The metal hinged enclosure provides mechanical protection and easy access for maintenance while the pre-populated 12-coupler layout simplifies installation and labeling for orderly cable management.
This surface‑mount hinged metal box is intended for indoor use where wall or cabinet mounting is possible; it is not a weatherproof or outdoor-rated enclosure. Installers requiring integrated cable management for high-density rack mounting or large patch fields may prefer full-sized rack panels. If fiber connectivity or shielded connector types are required, this specific unshielded CAT6A keystone configuration may not meet those needs.
Mount the metal hinged box to a suitable flat surface or inside a cabinet using appropriate fixings. Route and terminate horizontal copper cabling to the keystone jacks following standard wiring schemes (T568A or T568B) and test each link for continuity and performance up to CAT6A/10GbE specifications. Keystone couplers can be removed or replaced from the slim-line openings for reconfiguration or repair. Label each port for easy identification and close the hinged cover to provide mechanical protection after work is completed.
Use certified CAT6A keystone jacks and perform end-to-end testing after installation to ensure 10GbE link performance. Maintain appropriate bend radii for horizontal copper cables and avoid running the patch panel near strong electrical interference sources. For higher-density or shielded installations, evaluate rack-mount or shielded alternatives.