Residual Current Circuit Breaker ABB FH204 AC-40/0.03 40 A 4P
Leave your address - as soon as the price of the product goes down, you'll know about it right away
Residual Current Circuit Breaker ABB FH204 AC-40/0.03 40 A 4P
Residual Current Circuit Breaker ABB FH204 AC-40/0.03 40 A 4P
ABB FH204 AC-40/0.03 is a residual current circuit breaker that combines overcurrent protection with earth-leakage detection in a single 4-pole device. Rated for 40 A and with 30 mA residual current sensitivity, this RCBO-style device is designed to detect AC-type leakage currents and interrupt supply to protect people and equipment in TN and IT distribution systems. It is intended for integration into residential, commercial and light industrial distribution boards where combined short-circuit, overload and earth-leakage protection is required.
The ABB FH204 AC-40/0.03 provides coordinated overcurrent and residual current protection in one compact unit, reducing the number of devices and simplifying wiring in distribution panels. With a 4-pole construction it ensures simultaneous disconnection of all conductors including neutral in three-phase systems. The 30 mA sensitivity helps reduce the risk of electric shock to users while the device’s rated 40 A capacity meets typical feeder and circuit loads in small commercial and residential applications. Installation is compatible with standard DIN-rail mounting and common distribution board layouts.
This device is specified to respond to AC-type residual currents at 30 mA sensitivity; it may not be suitable for installations where detection of pulsating DC or mixed-frequency leakage currents is required unless the system is verified as compatible. The 40 A rated current limits its use on circuits that routinely carry higher continuous currents; larger feeders will require devices with higher current ratings.
Mount the ABB FH204 AC-40/0.03 on a standard DIN rail inside a suitable distribution board and connect line and load conductors according to the electrical schematic of the installation, ensuring correct phase and neutral arrangement for four-pole operation. Verify proper tightening of terminals and that the device is accessible for manual testing. After wiring, apply supply and perform the built-in test routine and any external insulation and continuity checks required by local regulations. Regularly test the residual current function according to maintenance schedules to confirm continued protection.
Install and commission the device in accordance with local electrical codes and manufacturer installation instructions. Perform periodic functional tests of the residual current trip mechanism and incorporate the device into the facility’s preventive maintenance programme to ensure reliable protection against electric shock and leakage faults.
{{highlightedFeature.featureTitle}}:
{{getProductFeatureValueById(product, highlightedFeature.featureId)}}
| Warehouse | Stock | Delivery to the store | Store Price | |
| WH360 | 7 | Monday Best delivery | 31.99 € Best price | |
| WH357 | 7 | 08.07.2026 | 40.49 € |
|
31.99 €
Stock:
7
Delivery Date:
Monday
Best delivery
Warehouse: WH360
|
|
40.49 €
Stock:
7
Delivery Date:
08.07.2026
Warehouse: WH357
|