Differential (Residual Current) Circuit Breaker EFI-P4 40A 4P 30mA Type A 10kA
The Differential (Residual Current) Circuit Breaker EFI-P4 40A 4P 30mA Type A 10kA combines residual-current detection with overcurrent protection in a single four-pole device. It is rated for 40 A nominal current and provides 30 mA residual sensitivity with Type A detection, which covers alternating current leakage and pulsating direct current faults. The unit features a breaking capacity of 10 kA and is designed for installation in household and light-commercial distribution boards to reduce risk of electric shock and fire due to earth-leakage currents.
The device integrates residual-current monitoring and short-circuit/overcurrent protection, reducing component count in a distribution board and simplifying wiring. Type A sensitivity improves detection of AC and pulsating DC leakage that can occur with modern electronic loads and appliances. A 4-pole design enables simultaneous disconnection of all conductors in three-phase or three-phase-with-neutral systems, improving safety during fault conditions. The 10 kA breaking capacity ensures the device can interrupt typical fault currents found in domestic and small commercial installations.
This unit is intended for installations where a 40 A nominal rating and 30 mA residual sensitivity are appropriate; it is not suitable where higher continuous currents or different sensitivity levels are required. It also does not provide selective discrimination with upstream protection unless coordination is verified; in larger installations additional protective coordination may be necessary.
Install the device on a standard DIN rail inside the distribution board according to local wiring regulations. Connect line and neutral conductors to the labeled terminals, ensuring correct phase sequence for three-phase circuits. Verify that upstream and downstream protection devices are compatible and that the device is mounted where tripping is accessible for maintenance. Test the residual-current function after installation and at regular intervals using a test button or an appropriate test instrument following local safety standards.
For safe operation, combine the differential circuit breaker with correctly rated upstream overcurrent protection and follow local electrical codes. Perform functional tests after installation and during regular maintenance, and replace the device if it shows signs of mechanical or electrical failure.